Scada Jobs

6 were found based on your criteria {{ paging.total|number:0 }} were found based on your criteria

show all
  • Hourly ({{ jobTypeController.getFacetCount("0")|number:0}})
  • Fixed Price ({{ jobTypeController.getFacetCount("1")|number:0}})
Fixed-Price - Expert ($$$) - Est. Budget: $300 - Posted
Hi, The Scope involves design engineering for Instrument and Control and Electrical work for the expansion of the existing Oil Storage Terminal in Africa. The project predominantly involves construction of four numbers product storage tanks, plant piping interconnecting the tanks as well as hooking up to the existing terminal, fire water tanks with associated automated fire fighting system, modification to the existing control panels as well as modification / addition to the existing PLC system. The Instruments mounted on the tanks are: a. Radar Type Tank Gauging System with tank side remote display unit. b. Temperature Transmitters c. Pressure Transmitters d. High Level Switch e. Low Level Switch f. Pressure Vacuum Relief Valves g. Motor Operated Body Valves as well as MOVs for the plant piping with necessary interlocking as per P&ID. Fire Fighting System a. The cooling system of the tanks are to be remotely activated from the control room, locally as well as interconnected with the nitrogen / LHD based fire detection system. b. The tank farm area will be provided with gas monitors and UV detectors integrated to the existing control room. c. Electrically operated Fire Pumps – 2 Numbers & Jockey Pump – 1 Number d. Diesel Driven Fire Water Pump. CCTV cameras to be installed and integrated with the existing system. Electrical Works consists of modification to the existing switch gear to accommodate the additional load on account the additional tanks, lighting, earthing, lightning protection and necessary modification on account of the new fire water pumps. Kindly find attached extracts from our contract (with our client) detailing the scope of works along with P & ID. We are looking at suitably qualified freelancers who were involved in independently handling similar works in the past & who can immediately take up this assignment. The design engineer is expected to visit the project site, if required and gather the required data. Any additional / missed out data required thereafter could be obtained from our project engineers. We could discuss the professional fees for the visit if any such need arises. The following are the documents to be generated by the design engineer. ELECTRICAL ELECTRICAL LOAD LIST ELECTRICAL SINGLE LINE DIAGRAM HAZARDOUS AREA CLASSIFICATION CABLE AND EARTHING LAYOUT CABLE TRENCH LAYOUT LIGHTING LAYOUT CABLE SCHEDULE CABLE SIZING VOLT DROP CALCULATIONS INSTRUMENTATION INSTRUMENTATION LOCATION & CABLE LAYOUT INSTRUMENT INDEX CONTROL FUNCTION SCHEMATIC INSTRUMENT LOOP DIAGRAM HOOK UP DIAGRAM CABLE SCHEDULE JB SCHEDULE I/O LIST FOR DCS / PLC CABLE BLOCK DIAGRAM GRAPHICS FOR ADDITIONAL WHITE OIL TANKS MTO for all materials required for Instrumentation & Electrification including but not limited to Control System Modules, Specification and requirement of Marshalling and Local Control Panels, Cables, Lighting, Motor Control Centers, etc.
Skills: PLC & SCADA Electrical engineering Instrumentation
Fixed-Price - Intermediate ($$) - Est. Budget: $250 - Posted
Want to get an Electronic Data Sheet AOP built for an ABB ACS880 drive for ControlLogix over EtherNet/IP. Version 20 and later of Rockwell RSLogix5000 supports the following: Electronic Data Sheet AOP This feature allows select devices that have properly configured EDS sheets to integrate directly with Logix without the need for a device profile. This improves the flexibility of the Integrated Architecture™ by providing a richer integrated experience to more devices. ABB already has an EDS file for their drive ACS880. It may not be the most clean but I want somebody to try this. There may be a few different EDS files we need to look at to make sure we have the correct one. I want to make the integration into a ControlLogix system very easy for an ABBACS880 using the ODVA Drive Profile. Currently I import the AOI and UDT's separately and build the drive in the IO tree manually using a generic ethernet module. According to our customer with an AOP the user when importing it will already contain the EDS and build out the tags with names like the UDT. So the manual step of importing an AOI, UDT, and EDS separately would not have to be done. I have an ODVA assembly instance I want to use along with the EDS file from ABB,
Skills: PLC & SCADA PLC Programming
Fixed-Price - Intermediate ($$) - Est. Budget: $500 - Posted
We have an old machine that had vol memory and lost the program we have a program in mwp file structure but need help converting it to something that the allen bradley slc 500 can read and also help with the upload into the machine. The machine is a l bar sealing machine ......plc programming
Skills: PLC & SCADA PLC Programming